ProbeSure™ OneStep RT-PCR Master Mix is a 2x master mix for one-step reverse transcription and PCR from RNA template with hydrolysis probe-based assays, in endpoint or real-time mode. This user guide covers ROX options, primer and probe concentrations, RNA handling, a 10 µL reaction setup, the thermal cycling protocol with an RT step, signal detection and data analysis.

ProbeSure OneStep RT-PCR at a glance

  • Applications: one-step RT-PCR from RNA with hydrolysis probes, endpoint or real-time
  • Compatible probes: TaqMan™, ZEN™ and BHQ™/BHQplus™ probes
  • ROX options: no ROX, low (25 nM) or high (500 nM)
  • Pack sizes: 1 mL to 250 mL, 2x concentration
  • Typical concentrations: primers 300-900 nM, probes 100-200 nM
  • Thermal cycling: RT at 50 °C for 10-30 min, 95 °C for 10-15 min, then 35-45 cycles of 95 °C and 57-65 °C
  • Storage: -20 °C / -80 °C for two years, or 4 °C for two weeks protected from light

Working with DNA instead of RNA? See the ProbeSure™ Master Mix user guide.

1. PRODUCT DETAILS

ProbeSure™ OneStep RT-PCR Master Mix product table with part numbers RT-PSURE-01 to RT-PSURE-12, no ROX, low ROX (25 nM) or high ROX (500 nM), pack sizes from 1 mL to 250 mL, 2x concentration

2. DESCRIPTION

ProbeSure OneStep RT-PCR Master Mix is designed for highly specific and sensitive one-step reverse transcriptase (RT) fluorescently-reporting PCR using RNA template. The master mix includes optimised components which allow reverse transcription and subsequent PCR amplification to take place in the same reaction well. ProbeSure OneStep RT-PCR Master Mix may be used in endpoint or real-time modes.

ProbeSure OneStep RT-PCR Master Mix is designed for use in PCR genotyping applications with hydrolysis probe-based assays. It can be used with a variety of fluorogenic probe types including TaqMan™, ZEN™ probes and BHQ™/BHQplus™ probes. It is not intended for use as a general PCR master mix or for HRM applications.

ProbeSure OneStep RT-PCR Master Mix contains all the necessary components to carry out the reaction (except RNA and primers/probes) and is supplied at 2x concentration. It is formulated with dTTP as this improves reaction sensitivity and efficiency when compared to mixes containing dUTP.

3. STORAGE AND SHELF LIFE

ProbeSure OneStep RT-PCR Master Mix is shipped on blue ice. Upon arrival, store at -20˚C/-80˚C (stable for two years); multiple freeze / thaw cycles are not recommended. The mix can also be stored at 4˚C for two weeks (protected from light).

4. SAFETY WARNINGS AND PRECAUTIONS

This product should only be handled by trained laboratory personnel. It is advisable to wear suitable personal protective equipment (PPE) when using the product. In case of contact with skin or eyes, wash immediately with water.

5. KIT COMPONENTS

ProbeSure OneStep RT-PCR Master Mix (supplied at 2x concentration), containing a specifically engineered Taq polymerase, dNTPs, buffer, performance enhancers, MgCl2, passive reference dye (ROX) and Reverse Transcriptase (RT) (200x).

REQUIRED COMPONENTS

  • Fluorescent plate reader or qPCR machine capable of reading the fluorophores used
  • PCR plate or equivalent and appropriate optically clear seal
  • Template RNA
  • PCR-grade water
  • Primers and fluorogenic hydrolysis probes (or both combined into an assay)

6. ROX COMPATIBILITY

ProbeSure OneStep RT-PCR Master Mix is supplied without ROX, or with low or high ROX levels. Please ensure compatibility between the ROX level of the master mix and the qPCR instrument. Should you require further assistance, please contact your qPCR instrument/plate reader manufacturer, or contact 3CR Bioscience’s Technical Support team.

If a fluorescent plate reader is used instead of a qPCR machine, it is recommended that the high ROX version of the ProbeSure OneStep RT-PCR Master Mix is used.

7. PRIMERS AND PROBES

The optimal primer and fluorogenic hydrolysis probe concentrations should be determined empirically. Primer concentrations of 300 – 900 nM and probe concentrations of 100 – 200 nM are generally suitable for most applications.

8. RNA QUALITY AND QUANTITY

RNA is highly susceptible to ubiquitous RNases. Care should be taken when handling the samples. An empirical optimisation of RNA concentration should be carried out by testing a sample dilution range.

9. CONTROLS

To improve confidence in the data, control samples should be used on the PCR plate in addition to the test samples. Negative controls (no-template controls, or NTCs) should always be used and consist of the same buffer used to hydrate the RNA samples, dispensed into several wells of the PCR plate. Positive controls can also be used, if available, and should consist of RNA samples of known sequence.

When viewing the data, NTCs should show no amplification, giving confidence that any amplification observed is real. Any amplification observed in the NTC wells would indicate contamination or non-specific amplification. The positive control samples should amplify as expected for their sequence.

10. REACTION PROCEDURE

A. ARRAYING TEMPLATE RNA

A liquid-handling system appropriate to the number of RNA samples to array should be used. RNA samples can also be arrayed manually if working with a low number of samples.

B. REACTION ASSEMBLY

Ensure the components are defrosted thoroughly, mix and centrifuge briefly prior to use. The enzymes used in ProbeSure OneStep RT-PCR Master Mix are modified such that they are completely inactive at ambient temperature. Such inactivation allows bench top reaction assembly without leading to primer-dimer issues and other side reactions. The enzymes are reactivated during the initial stage of thermal cycling.

COMPONENTFINAL CONCENTRATIONVOLUME FOR 10 µL REACTION (µL)
ProbeSure OneStep RT-PCR Master Mix (2x)1x5
Primer(s)300-900 nMVariable
Probe(s)100-200 nMVariable
RNA templateVariableVariable
Nuclease-free water–To 10 µL
TOTAL–10 µL
Table 1. Reagent volumes for total reaction mix.

A total reaction mix should always be made to eliminate well-to-well variation of component concentrations. Assemble the total reaction mix using Table 1 as a guide.

ProbeSure OneStep RT-PCR Master Mix can be used in reaction volumes of any size, including volumes (below 1 µL) in the appropriate PCR plate. It is important that ProbeSure OneStep RT-PCR Master Mix is used at a final concentration of 1x.

C. TOTAL REACTION MIX DISPENSING & PLATE SEALING

The total reaction mix must now be dispensed into the PCR plate wells. As with DNA dispensing, use a liquid-handling system that is appropriate to the scale of the work. Once the total reaction mix has been dispensed, the PCR plate must be sealed with an optically clear seal and centrifuged to ensure all components are at the bottom of the wells.

ProbeSure OneStep RT-PCR Master Mix can be used with any standard Peltier-based or water-bath thermal cycler. If used in real-time mode, any appropriate qPCR instrument may be used, and the fluorescent data captured at each cycle. Use the thermal cycling protocol detailed in Table 2.

D. THERMAL CYCLING

Place the plate on a thermal cycler or qPCR instrument and carry out the thermal cycling step. The thermal cycling protocol used will vary with probe type but a guide to appropriate conditions is shown in Table 2.

ProbeSure™ OneStep RT-PCR thermal cycling guide: reverse transcription at 50 °C for 10-30 min, 95 °C for 10-15 min, then 35-45 cycles of 95 °C and 57-65 °C
Table 2. Thermal cycling guide for ProbeSure OneStep RT-PCR Master Mix reactions.
ProbeSure™ OneStep RT-PCR recycling protocol: 3 additional cycles of 94 °C for 10-15 seconds and 57-65 °C for 60 seconds
Table 3. Thermal cycling conditions for recycling ProbeSure OneStep RT-PCR Master Mix reactions

E. FLUORESCENT SIGNAL DETECTION

After thermal cycling is complete, the fluorescent signal is detected and assessed by reading the plate with a fluorescent plate reader or a qPCR instrument in endpoint or real-time modes. If sufficiently defined genotype clusters are not obtained after the initial thermal cycling protocol, the plate should be cycled for an additional three cycles using the conditions detailed in Table 3 and read/analysed again. The additional cycling can be repeated until tight and well separated clusters are observed, though this is rarely required.

If analysing in real-time, data acquisition should be carried out during the annealing/extension step of each cycle.

F. INTERPRETATION OF DATA

Endpoint data analysis and interpretation can be done using cluster analysis software, a qPCR instrument or alternatively can be carried out in Microsoft Excel.

ROX passive reference dye can also be used to eliminate the effect of well-to-well liquid volume differences from the resultant cluster plot data. The inclusion of a passive reference leads to tighter clustering and, as a result, more accurate scoring of data.

Real-time data analysis is carried out using the qPCR instrument software.

11. ORDERING INFORMATION

For ordering details, please visit www.3crbio.com.

12. SUPPORT

If you require any support with the use of ProbeSure OneStep RT-PCR Master Mix or other 3CR Bioscience products, please contact our Technical Support team on support@3crbio.com.

For Research Use Only. Not for use in diagnostic procedures.

3CR Bioscience disclaims all warranties with respect to this documentation.

The purchase of this product conveys to the purchaser the limited, non-transferable right to use the purchased amount of the product only to perform internal research for the sole benefit of the purchaser. No right to resell this product or any of its components is conveyed expressly or by implication. This product is for internal research purposes only and is not for use in commercial applications of any kind, including, without limitation, quality control and commercial services such as reporting the results of purchaser’s activities for a fee or other form of consideration.

TaqMan™ is a trademark of Roche Molecular Systems, Inc.
Zen™ Probes is a trademark of Integrated DNA Technologies, Inc.
BHQ™ Probes and BHQplus™ Probes are trademarks of LGC Biosearch Technologies


©2023 3CR Bioscience Ltd. All rights reserved. Intended for molecular biology applications. This product is not intended for the diagnosis, prevention, or treatment of a disease.

MORE POSTS

PACE® 2.0 Genotyping Master Mix user guide shown on a tablet with the 3CR Bioscience logo
PACE® 2.0 GENOTYPING MASTER MIX – USER GUIDE
Running SNP or Indel genotyping with PACE® 2.0? This guide walks you through every step, from choosing the right ROX level and DNA input to reaction volumes, thermal cycling and reading your cluster plots, so you get tight, well-separated clusters first time.
PACE® Multiplex Master Mix (Endpoint) user guide shown on a tablet with the 3CR Bioscience logo
PACE® MULTIPLEX MASTER MIX (ENDPOINT) – USER GUIDE
Want to genotype two SNPs, or detect up to four targets, in a single well? This step-by-step guide shows you how to set up PACE® Multiplex Master Mix (Endpoint), from assay assembly and reaction volumes to thermal cycling, four-colour reading and clean cluster plots.
PACE® OneStep RT-PCR Master Mix user guide shown on a tablet with the 3CR Bioscience logo
PACE® ONESTEP RT-PCR MASTER MIX – USER GUIDE
Want reverse transcription and PCR in a single well? This step-by-step guide shows you how to set up PACE® OneStep RT-PCR Master Mix, from assay assembly and RNA handling to a 5 µL reaction, thermal cycling and clear cluster plots.

Our product portfolio for your PCR genotyping workflow

Our portfolio of products and services include PACE® genotyping chemistry, instruments, and lab services to streamline every step of your workflow. Designed for life sciences, biotech, and agricultural research, our high-performance reagents, reliable instruments, and expert lab support help you achieve accurate, consistent results while reducing time and costs – making science affordable.

[fibosearch]
This field is for validation purposes and should be left unchanged.
Name(Required)

Contact us

Resolve Genotyping Challenges. With One Practical Guide.

From failed amplification to scattered cluster plots — this guide provides structured, expert-backed solutions for the 7 most common PACE® genotyping issues.

"(Required)" indicates required fields

This field is for validation purposes and should be left unchanged.
I’d like to sign up for the newsletter

MEET OUR TEAM

Steve AsquithManaging Director
Steve began his career in the Genetics Division of GlaxoSmithKline, as part of the team establishing GSK’s high-throughput core genotyping laboratory. Steve joined KBioscience when it was first founded in 2002 and was a key driver in taking the company from a small start-up to a multi-national service laboratory, quickly growing the company’s revenue to over $7.5M p.a. Following the acquisition of Kbioscience by LGC in 2011, Steve was appointed Global Director of Operations for LGC Genomics, responsible for over 100 staff in Europe and N. America, successfully elevating the genotyping products and service business. Steve held a crucial leadership role until he left in 2016. In 2017 Steve joined forces with John Holme to create 3CR Bioscience, a new company with a mission to deliver outstanding, customer-focused genotyping products with innovation and affordability at its core.
Dr. John HolmeTechnical Director

John joined KBioscience shortly after it was founded, in 2003, and became Head of Technical Development, building the company’s genotyping and DNA extraction product portfolio and service delivery until 2011 when it was acquired by LGC. Post-acquisition, John was appointed Head of Technical Group for LGC Genomics, in charge of all Research & Development and Technical Support activities for the company. In this role John continued to build on the high-quality products and services provided to the companies growing customer base.

During the 19 years John has worked in commercial R&D, he has co-invented numerous highly successful products including PACE®, ProbeSure, KASP™, KlearKall, KlearGene, KlearAmp and KlearTaq™, creating breakthrough offerings in genotyping and extraction and generating huge revenues for the companies he has worked in. In 2017, he joined forces with Steve Asquith and started 3CR Bioscience. John is dedicated to developing outstanding, innovative genotyping products and providing the very best technical support to customers globally.

Dr. Nisha JainOperations Director

Nisha has been innovating since the start of her career at Geneform Technologies developing Iso-thermal Genotyping Technologies. Nisha joined KBioscience in 2008, as Senior R&D Scientist and key account Technical Support Scientist, developing KASP and Klearkall performance and coinventing two further versions of KASP.

Nisha has more than 15 years’ experience working in molecular biology and genotyping technologies, with extensive experience in the areas of R&D, Quality Assurance and Customer Technical Support. She has technically assisted many giants of the industry with their protocol development and troubleshooting and continues to deliver high-quality support and guidance. In 2018, Nisha joined 3CR Bioscience as Operations Director where she continues to develop PACE and ProbeSure for an increasing range of applications, and to grow 3CR Bioscience’s new product pipeline. Nisha is dedicated to developing outstanding, innovative genotyping products and providing the very best technical support to customers globally.

Nazma SaffinGeneral Manager

For 20 years Nazma Saffin has worked and gained extensive expertise within the genotyping sector. Working at Kbioscience and then LGC, she has held operational leadership posts responsible for manufacturing and laboratory services. With experience of ISO 9001 implementation, production scale up and LEAN operations, Nazma has successfully led highly profitable production departments. Joining 3CR Bioscience in 2022, Nazma is committed to delivering operational excellence.

Greig PollandAutomation and Support Manager

Greig is a hands-on automation specialist and team leader with a strong background in laboratory and industrial automation. He has spent over 25 years developing, installing, and supporting automated systems that transformed laboratory workflows. During this time, Greig worked closely with scientists and engineers to tailor automation solutions for genotyping and molecular biology, an experience that sparked his lasting passion for combining technology with practical science.

Since then, Greig has built on that foundation through leadership roles where he leads automation and support operations. He’s known for being approachable, commercially minded, and deeply committed to helping teams and customers get the best from their technology.

Whether managing a complex automation rollout or helping a customer troubleshoot in real time, Greig brings a thoughtful, collaborative approach that keeps people ,not just machines, at the centre of what he does.

Daniel LawsonMarketing Manager
Daniel is a strategically minded marketing and communications professional with over a decade of experience delivering integrated, multi-channel campaigns across healthcare, legal and not-for-profit sectors. He has a strong track record in building brand visibility, driving engagement and supporting revenue growth through audience-focused marketing.
Prior to joining 3CR Bioscience in 2025, Daniel held senior marketing roles where he led strategic communications, managed brand development and delivered high-impact digital and content campaigns. His experience spans SEO, CRM, PR, events and stakeholder engagement, with a particular strength in translating complex messages into clear, compelling content.
At 3CR Bioscience, Daniel is responsible for shaping and executing the company’s marketing strategy, enhancing brand presence and supporting commercial growth through targeted, data-driven campaigns.